|
|
Features: • long life time • low power consumtion • US Patent Nr. 4.314.475
|
Technical Data |
|
Sensor type |
methan-CH4-TC-5% |
Measuring principle |
thermocatalytic; Pt + Pd on AI2O3 |
Measuring range |
0-100%LEL(0-5% vol. CH4) |
Resolution |
0.01 %CH4 |
Output Sensitivity |
25 mV/% CH4, ±5 mv |
Zero signal offset |
±30mV |
Operating Current |
50 mA ± 3mA |
Diffused power: |
120 mW |
Supply voltage (mV) |
2.7 V±0.10 V |
Linearity |
< ± 5 % FS |
Response time 1 90 (s) at 20°C |
< 15s |
Warm up/cooling time constant: |
0.08s |
Warm up/cooling total time: |
0.2s |
Long term zero drift: |
< ± 5% FS/month |
Long term sensitivity drift: |
< ± 5% FS/month |
Operation temperature range: |
- 20°Cto+50°C |
Operation humidity range: |
0-95% (non-condensed) |
Storage temperature: |
-40°C to +50°C |
Effect of humidity: |
no |
Sensor life expectancy: |
> 36 months |
Warranty: |
24 months |
Mechanical dimensions: |
diameter 15.5 mm, height 11.8 mm |
Dimension of catalytic cell: |
appr. 0.25 mm |
Mass: |
6 g |
Cross sensitivities: |
usual for thermocatalytic sensors |
Poison resistance: |
usual for thermocatalytic sensors |
|
|