Features:
• very long life time
• high reliability
• built-in transmitter |
Technical
Data |
|
Sensor type
|
Oxigen-O2-2E-30%
|
Measuring principle
|
amperometric 2-electrode-sensor
|
Measuring range
|
0-30% vol. O2
|
Sensitivity range
|
150-500 mV/20.8%vol.O2
|
Long term sensitivity drift
|
<15% per 3 years, <30% per 10 years
|
Deviation from linearity
|
<0.3% vol. O2 inside of range 0-30% vol. O2
|
Zero voltage at 20°C
|
<0.3% vol. O2
|
Response time 1 9o (s) at 20°C
|
<20 seconds, typical 12 seconds
|
Effect of temperature on sensitivity
|
<5% inside of range -20°C to +50°C, built-in transmitter with
temperature compensation
|
Pressure dependence
|
linear
|
Operating conditions
|
-35°C to +50°C; 0 to 98% r.H. (non-condensed)
|
Best storage conditions
|
+5°C to +20°C; 40 to 60% r.H.
|
Sensor life expectancy
|
>10 years at 20.8% vol.O2, at 20°C
|
Warranty
|
30 months
|
Dimensions
|
CTL-4 housing (4-Series) height 18 mm, diameter 20 mm
|
Sensor transmitter output
|
two pins, Ø 1.6 mm
|
Imput impedance of user's Electronic circuit
|
>2 MΩ, >2 MΩ by switch off of el. circuit
|
None cross sensitivity at 20°C by
|
Carbon monoxide <10%vol.
Carbon dioxide <30%vol.
Hydrogen <30%vol.
Mainly VOCs ~ %-range
|
|
|